OpenPV reads FAERS, a drug adverse-event system. Vaccine reports filed there are not VAERS reports.
← All causality assessments
Causality assessment · Coding artifact: the device named as the "reaction"

Copper intrauterine device and Foreign body in reproductive tract: is the FAERS signal real? FAERS data 14 September 2026

n=8,693 co-reports · PRR 89,124.5 · ROR 111,803.9
A written Bradford Hill assessment of one drug–event pair. The grade is a judgement about the signal, not a statement that this drug causes this event in any one person; FAERS counts are reports, not rates.
Coding artifact: the device named as the "reaction"

Copper intrauterine device ↔ Foreign body in reproductive tract

n=8,693 co-reports · PRR 89,124.5 · ROR 111,803.9

This is the single highest PRR in the entire dataset (89,124), and it is a pure coding artifact — included deliberately as the extreme counter-example. A copper intrauterine device is a physical object placed in the uterus; when a report mentions "foreign body in reproductive tract," that is a literal description of the device itself, not an adverse reaction the device caused. The PRR is astronomically high precisely because the reaction term is essentially unique to this product class, which guarantees disproportionality by construction. It is the clearest possible reminder that PRR measures the distinctiveness of what gets reported, not harm — the highest number on the page is also one of the least meaningful.

Methodological note, not a regulatory finding: the "foreign body" term describes the intrauterine device itself (a physical implant), a coding artifact of the reporting scheme rather than a biological effect.

Bradford Hill viewpointStatusNote
Temporality (necessary)n/aNot a biological effect — the term names the device
StrengthmetPRR 89,124 — but this measures coding specificity, not an effect
ConsistencymetConsistent with any report that mentions the IUD
Specificitynot establishedThe term just names the device; it carries no effect information
Biological gradientn/a—
Plausibilityn/aNo biological hypothesis — the device is a foreign body by definition
Coherencenot establishedFails coherence with any genuine adverse-reaction concept
Experimentn/a—
AnalogymetAnalogous to other device/administrative coding terms (e.g. "device malfunction")

This page's own qualitative read, not an automated/citation-gated assessment.

Not applicable in principle. A "foreign body" reaction term reflects the physical presence of the device, which no trial's adverse-event table would ever report as a drug-related event. There is no biological hypothesis here for a trial to confirm or refute.
OpenPV is a project of the Open Source Medicine Foundation. Sister site: Vaccine Data Navigator (vaccine evidence, schedules and VAERS data). Report an error